Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38494437

RESUMO

OBJECTIVE: This study sought to identify periprocedural risk predictors that affect long-term prognosis in patients with chronic obstructive pulmonary disease (COPD) undergoing isolated coronary artery bypass grafting (CABG). METHODS: All consecutive 4,871 patients undergoing isolated CABG between May 2005 and June 2021 were included. Patients with and without COPD were compared for baseline demographics and preoperative characteristics. A propensity-matched analysis was used to compare the 2 groups. The primary outcome was long-term incidence of all-cause death. RESULTS: After matching, 767 patients each were included in the COPD and non-COPD groups; mean age was 71.6 and 71.4 years (P = .7), respectively; 29.3% and 32% (P = .2) were women, respectively. Intraoperatively, median (IQR) operating room time was higher in the COPD group than in the non-COPD group (5.9 [5.2-7.0] hours vs 5.8 [5.1-6.7] hours, respectively; P = .01). Postoperatively, intensive care unit stay (P = .03), hospital length of stay (P = .0004), and fresh frozen plasma transfusion units (P = .012) were higher in the COPD group than in the non-COPD group. Thirty-day mortality was not different between groups (1.3% in the COPD group vs 1% in the non-COPD group; P = .4). Median follow-up time was 4.0 years. The rate of all-cause death was higher in the COPD group than in the non-COPD group (138 patients [18.3%] vs 109 patients [14.5%], respectively; P = .042). Periprocedural risk predictors for all-cause death in patients with COPD were atrial fibrillation, diabetes, male sex, dialysis, ejection fraction less than 50%, peripheral vascular disease, and Society of Thoracic Surgeons Predicted Risk of Mortality score greater than 4%. CONCLUSION: Patients with COPD undergoing isolated CABG had a significantly higher incidence of all-cause death than those without COPD. Herein, risk predictors are provided for all-cause death in patients undergoing isolated CABG.


Assuntos
Doença da Artéria Coronariana , Doença Pulmonar Obstrutiva Crônica , Humanos , Masculino , Feminino , Resultado do Tratamento , Transfusão de Componentes Sanguíneos , Plasma , Ponte de Artéria Coronária/efeitos adversos , Prognóstico , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Fatores de Risco , Estudos Retrospectivos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38180892

RESUMO

OBJECTIVES: The aim of this study was to compare long-term prognosis after isolated coronary artery bypass grafting between white and black patients and to investigate risk factors for poorer outcomes among the latest. METHODS: All consecutive 4766 black and white patients undergoing isolated coronary artery bypass grafting between May 2005 and June 2021 at our institution were included. Primary outcomes were long-term incidence of all-cause death and major adverse cardiovascular and cerebrovascular events in black versus white patients. A propensity-matched analysis was used 2 compare groups. RESULTS: After matching, 459 patients were included in each black and white groups while groups were correctly balanced. The mean age was 70.4 vs 70.6 years old (P = 0.7) in black and white groups, respectively. Intraoperatively, mean operating room time and blood product transfusion, were higher in the black group while incidence of extubation in the operating room was higher in the white one. Postoperatively, hospital length of stay was higher in the black cohort. Thirty-day all-cause mortality was not different among groups. The median follow-up time was 4 years. Primary outcome of all-cause death was higher in the black versus the white, respectively. Major adverse cardiovascular and cerebrovascular events incidence was twice higher in the black compared to the white cohort (7.6% vs 3.7%, P = 0.013). Risk predictors for all-cause death and major adverse cardiovascular and cerebrovascular events in blacks were creatinine level, chronic obstructive pulmonary disease, ejection fraction <50% and preoperative atrial fibrillation. CONCLUSIONS: Racial disparities persist in a high-volume centre. Despite no preoperative difference, black minority has a higher incidence of major adverse cardiovascular and cerebrovascular events.

3.
EuroIntervention ; 20(1): 45-55, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37994042

RESUMO

BACKGROUND: Patients who are not candidates for traditional coronary artery bypass grafting (CABG) and amenable only for percutaneous coronary intervention (PCI) with stents can receive the "gold standard" left internal thoracic artery (LITA) to left anterior descending artery (LAD) anastomosis through robotic-assisted CABG and PCI to non-LAD coronary targets. AIMS: We aimed to analyse clinical outcomes of robotic-assisted CABG. METHODS: A total of 2,280 consecutive patients who had undergone robotic-assisted CABG between May 2005 and June 2021 were included in our study. Robotic-assisted LITA harvest was followed by LITA-LAD manual anastomosis through a 4 cm left thoracotomy. Hybrid coronary intervention (HCR) consists of stent implantation in a non-LAD coronary artery performed within 7 days after robotic-assisted LITA-LAD. We performed a propensity-adjusted analysis comparison after dividing all robotic-assisted CABG patients into three time periods: 2005-2010, 615 patients; 2011-2016, 904 patients; and 2017-2021, 761 patients. RESULTS: The mean age increased from 64.5 years in the first time period to 65.8 years in the second time period to 68.1 years in the third (p<0.0001). Operative time was progressively reduced in the three periods (6.4; 6.2; 5.5 hours; p<0.001). The incidence of conversion to sternotomy remained similar for each period (1.8%; 1.7%; 1.5%; p=0.53). Thirty-day mortality in the three periods included 9 (1.4%), 9 (1.0%), and 7 (0.9%) patients, respectively (p=0.91), while 8 (0.3%) patients had PCI with stents in the entire group. The mean follow-up for the entire population was 4.2 years. At follow-up, the rates of all-cause death, major adverse cardiac and cerebrovascular events, non-fatal stroke, and repeat revascularisation with stents were significantly decreased from the first to the last period (pË0.0001). CONCLUSIONS: Robotic-assisted CABG and HCR provide good long-term outcomes in patients who are not candidates for conventional CABG.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Humanos , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
7.
Struct Heart ; 7(2): 100118, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37275584

RESUMO

Background: Paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) is frequent and the impact of mild PVL on outcomes remains uncertain. Our study aimed to evaluate the impact of PVL on TAVI outcomes. Methods: To analyze late outcomes of patients after TAVI according to the presence and severity of PVL, PubMed/MEDLINE, EMBASE and Google Scholar were searched for studies that reported rates of all-cause mortality/survival and/or rehospitalization and/or cardiovascular mortality accompanied by at least one Kaplan-Meier curve for any of these outcomes. We adopted a 2-stage approach to reconstruct individual patient data based on the published Kaplan-Meier graphs. Results: Thirty-eight studies with Kaplan-Meier curves met our eligibility criteria including over 25,000 patients. Patients with any degree of PVL after TAVI had a significantly higher risk of overall mortality (hazard ratio (HR), 1.52; 95% confidence interval (CI), 1.43-1.61; p < 0.001), rehospitalization (HR, 1.81; 95% CI, 1.54-2.12; p < 0.001), and cardiovascular mortality (HR, 1.52; 95% CI, 1.33-1.75; p < 0.001) over time. These findings remained consistent when we stratified the results for the methods of assessment of PVL (i.e., echocardiography vs. angiography) and PVL severity. Both moderate/severe PVL and mild PVL were associated with increased risk of overall mortality (p < 0.001), rehospitalization (p < 0.001), and cardiovascular mortality (p < 0.001) during follow-up. Conclusions: Patients with PVL, even if mild, experience higher risk of all-cause mortality, rehospitalization, and cardiovascular mortality following TAVI. These findings provide support to the implementation of procedural strategies to prevent any degree of PVL at the time of TAVI.

8.
Innovations (Phila) ; 18(2): 167-174, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37129060

RESUMO

OBJECTIVE: Since there are concerns about the durability of mitral valve repair (MVRp) with minimally invasive techniques in patients with mitral regurgitation (MR), we aimed to evaluate the long-term outcomes of these sternal-sparing approaches when compared with conventional approaches with sternotomy in patients undergoing MVRp. METHODS: We performed a systematic review according to a preestablished protocol and performed a pooled analysis of Kaplan-Meier-derived reconstructed time-to-event data from studies with longer follow-up comparing sternal-sparing versus sternotomy approaches for MVRp. Our outcomes of interest were survival, freedom from recurrent MR, and freedom from reoperation. RESULTS: Eleven studies met our eligibility criteria comprising 7,596 patients with follow-up (sternal sparing, n = 4,246; sternotomy, n = 3,350). Patients who underwent sternal-sparing MVRp had a significantly lower risk of mortality over time compared with patients who underwent MVRp with sternotomy (hazard ratio [HR] = 0.29, 95% confidence interval [CI]: 0.23 to 0.36, P < 0.001) in the overall analysis. However, we found no statistically significant difference between the groups in the sensitivity analysis with adjusted populations (HR = 0.85, 95% CI: 0.63 to 1.15, P = 0.301). Regarding the outcomes freedom from recurrent MR and freedom from reoperation, we found no statistically significant differences between the groups in the follow-up in both overall and sensitivity analyses. CONCLUSIONS: In comparison with MVRp with sternotomy approaches, sternal-sparing MVRp was not associated with worse outcomes in terms of survival, recurrent MR, and reoperations over time.


Assuntos
Insuficiência da Valva Mitral , Esternotomia , Humanos , Esternotomia/métodos , Valva Mitral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência da Valva Mitral/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
9.
AJOG Glob Rep ; 3(2): 100183, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37229152

RESUMO

BACKGROUND: Outcomes of robotic-assisted coronary artery bypass grafting in pregnant women have not been assessed. OBJECTIVE: This study aimed to understand the importance of minimally invasive robotic-assisted coronary artery bypass grafting in pregnant woman with coronary artery disease. We describe the case of a G3P1011 woman at 19+6 weeks' gestation presenting with a non-ST myocardial infarction treated with off-pump hybrid robotic-assisted revascularization. STUDY DESIGN: This study describes the surgical approach for a pregnant woman presenting with non-ST myocardial infarction treated with hybrid robotic-assisted revascularization. RESULTS: A coronary angiography demonstrated a culprit lesion of 90% stenosis in the left anterior descending coronary artery and an 80% stenosis in the right coronary artery. Because of the high rate of complications with traditional coronary artery bypass grafting, the heart team opted for hybrid robotic-assisted revascularization and the postoperative recovery was uneventful. CONCLUSION: Robotic coronary artery bypass grafting can be the preferred surgical choice to decrease maternal and fetal mortality in patients undergoing coronary artery bypass grafting, and it is an important tool in the surgical armamentarium.

10.
Artigo em Inglês | MEDLINE | ID: mdl-37074251

RESUMO

OBJECTIVE: To investigate outcomes after aortic root allograft reoperation, identify risk factors for morbidity and mortality, and describe practice evolution since publication of our 2006 allograft reoperation study. METHODS: From January 1987 to July 2020, 602 patients underwent 632 allograft-related reoperations at Cleveland Clinic: 144 before 2006 (early era, which suggested radical explant was superior to aortic-valve-replacement-within-allograft [AVR-only]), and 488 from 2006 to present (recent era). Indications for reoperation were structural valve deterioration in 502 (79%), infective endocarditis in 90 (14%), and nonstructural valve deterioration/noninfective endocarditis in 40 (6.3%). Reoperative techniques included radical allograft explant in 372 (59%), AVR-only in 248 (39%), and allograft preservation in 12 (1.9%). Perioperative events and survival were assessed among indications, techniques, and eras. RESULTS: Operative mortality by indication was 2.2% (n = 11) for structural valve deterioration, 7.8% (n = 7) in those with infective endocarditis, and 7.5% (n = 3) for nonstructural valve deterioration/noninfective endocarditis, and by surgical approach 2.4% (n = 9) after radical explant, 4.0% (n = 10) for AVR-only, and 17% (n = 2) for allograft preservation. Operative adverse events occurred in 4.9% (n = 18) of radical explants and 2.8% (n = 7) of AVR-only procedures (P = .2). Patients undergoing radical explants received larger valves than those undergoing AVR-only (median, 25 vs 23 mm). CONCLUSIONS: Aortic root allograft reoperations present a technical challenge but can be performed with low mortality and morbidity. Radical explant offers outcomes similar to AVR-only while allowing for implant of larger prostheses. Increasing experience with allograft reoperations has permitted excellent outcomes; thus, risk of reoperation should not dissuade surgeons from using allografts for invasive aortic valve infective endocarditis and other indications.

11.
Catheter Cardiovasc Interv ; 101(7): 1203-1213, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37070459

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is associated with higher risk of mortality and rehospitalization for heart failure. Efforts to prevent conduction abnormalities (CA) requiring PPI after TAVI should be made. The membranous septum (MS) length and its interaction with implantation depth (ID-ΔMSID) could provide useful information about the risk of CA/PPI following TAVI. OBJECTIVES: To identify MS length and ΔMSID as predictors of CA/PPI following TAVI. METHODS: Study-level meta-analysis of studies published by September 30, 2022. RESULTS: Eighteen studies met our eligibility including 5740 patients. Shorter MS length was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: odds ratio [OR] 1.60, 95% confidence interval [CI] 1.28-1.99, p < 0.001). Similarly, lower ΔMSID was associated with a significantly higher risk of CA/PPI (per 1 mm decrease: OR 1.75, 95% CI 1.32-2.31, p < 0.001). Meta-regression analyses revealed a statistically significant modulation of the effect of shorter MS length and lower ΔMSID on the outcome (CA/PPI) by balloon postdilatation (positive regression coefficients with p < 0.001); with increasing use of balloon postdilatation, the effect of shorter MS length and lower ΔMSID on the outcome increased. MS length and ΔMSID demonstrated excellent discriminative abilities, with diagnostic ORs equaling 9.49 (95% CI 4.73-19.06), and 7.19 (95% CI 3.31-15.60), respectively. CONCLUSION: Considering that short MS length and low ΔMSID are associated with higher risk of CA and PPI, we should include measurement of MS length in the pre-TAVI planning with MDCT and try to establish optimal ID values before the procedure to avoid CA/PPI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Fatores de Risco , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
12.
Catheter Cardiovasc Interv ; 101(3): 639-650, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36655511

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) is a common complication after transcatheter aortic valve implantation (TAVI). The cusp-overlap view (COV) was adopted to reduce PPI risk after TAVI with self-expandable valves (SEVs); however, the evidence remains scarce. We performed a systematic review with meta-analysis comparing COV and the standard coplanar view (CPV) technique to evaluate their effectiveness and safety. METHODS: Following the PRISMA statement, data were extracted from studies published by August 2022 and found in PubMed/MEDLINE, EMBASE, CENTRAL/CCTR, ClinicalTrials.gov, SciELO, LILACS, and Google Scholar. The primary outcome of interest was post-procedural PPI and the secondary outcomes were new left bundle branch block (LBBB), moderate/severe paravalvular leak (PVL), valve dislocation (pop-out); need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, implantation depth (mm), and post-TAVI mean gradients (mmHg). RESULTS: Eleven studies met our eligibility criteria and included 1464 patients in the COV group and 1743 patients in the CPV group. Patients who underwent TAVI with COV had lower risk of PPI (odds ratio 0.48; 95% confidence interval [CI] 0.33-0.70; p = 0.001) and higher implantation depths with COV (mean difference -0.83; 95% CI -1.2 to -0.45; p < 0.001). We did not observe any statistically significant differences in the rates of new LBBB, moderate/severe PVL, valve dislocation, need of second transcatheter heart valve, 30-day mortality, stroke, conversion to surgery, coronary obstruction, and post-TAVI mean gradients (mmHg). CONCLUSION: In TAVI with SEVs, the application of COV is associated with lower risk of PPI compared with the standard CPV without increasing risk for adverse outcomes.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Arritmias Cardíacas/etiologia , Bloqueio de Ramo/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
13.
Surg Endosc ; 37(2): 1107-1113, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36123544

RESUMO

BACKGROUND: Over the last 20 years, the prevalence of severe obesity (body mass index ≥ 35 kg/m2) has almost doubled. This condition increases the challenge of laparoscopic adrenalectomy (LA) by creating problems with instrument reach, adequate exposure, and visualization. The aim was to compare perioperative outcomes of laparoscopic versus robotic adrenalectomy (RA) in severely obese patients. METHODS: This was an institutional review board-approved retrospective study. Prospectively collected clinical parameters of patients who underwent LA versus RA between 2000 and 2021 at a single center were compared using Mann-Whitney U, ANOVA, Chi-square, and multivariate regression analysis. Continuous data are expressed as median (interquartile range). RESULTS: For lateral transabdominal (LT) adrenalectomies, skin-to-skin operative time (OT) [164.5 (71.0) vs 198.8 (117.0) minutes, p = 0.006] and estimated blood loss [26.2 (15.0) vs 72.6 (50.0) ml, p = 0.010] were less in RA versus LA group, respectively. Positive margin rate, hospital stay and 90-day morbidity were similar between the groups (p = NS). For posterior retroperitoneal (PR) approach, operative time and perioperative outcomes were similar between LA and RA groups. Multivariate analysis demonstrated robotic versus laparoscopic technique (p = 0.006) to be an independent predictor of a shorter OT. CONCLUSION: There was a benefit of robotic over the laparoscopic LT adrenalectomy regarding OT and estimated blood loss. Although limited by the small sample size, there was no difference regarding perioperative outcomes between RA and LA performed through a PR approach.


Assuntos
Neoplasias das Glândulas Suprarrenais , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Adrenalectomia/métodos , Estudos Retrospectivos , Laparoscopia/métodos , Obesidade/cirurgia , Neoplasias das Glândulas Suprarrenais/cirurgia
14.
Trends Cardiovasc Med ; 33(7): 458-467, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35513298

RESUMO

Based on previous meta-analyses including immediate/1-year results, individuals with bicuspid aortic valve (BAV) stenosis can undergo TAVI with similar outcomes as those with tricuspid aortic valve (TAV), but with higher rates of periprocedural complications. The widespread belief is that BAV patients would have poor results in comparison with TAV patients after TAVI over time. Therefore, we performed a systematic review with meta-analysis with reconstructed time-to-event data of studies published by January 2022 to compare late outcomes of patients with BAV versus TAV who underwent TAVI. This approach reconstructs individual patient data (IPD) based on the published Kaplan-Meier graphs. Ten studies met our eligibility criteria, including 9,071 patients with BAV and 171,070 patients with TAV. Patients with BAV had a significantly lower risk of mortality (HR 0.70, 95%CI 0.65-0.77, P<0.001), however, this result was driven by populations in which the risk score was statistically significantly lower in the BAV group (HR 0.69, 95%CI 0.63-0.76, P<0.001) and by populations in which the BAV group was statistically significantly younger (HR 0.72, 95%CI 0.64-0.81, P<0.001). In patients with selected BAV anatomy deemed favorable for TAVI, we did not find worse survival over time in comparison with patients with TAV; however, the follow-up beyond 1 year remains limited in the studies and we need more investigation for specific bicuspid anatomies with longer follow-up. Most importantly, randomized controlled trials including exclusively BAV patients treated with TAVI versus SAVR are warranted.

15.
J Thorac Cardiovasc Surg ; 166(3): 805-815.e1, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-35525802

RESUMO

OBJECTIVE: A number of publicly available rating algorithms are used to assess hospital performance in coronary artery bypass grafting (CABG). However, concerns remain that these algorithms fail to correlate with each other and inadequately capture the case complexity of individual center practices. METHODS: Composite star ratings for isolated CABG from the Society of Thoracic Surgeons public reporting database were extracted for 2018-2019. U.S. News & World Report Best Hospitals was used to extract CABG ratings as well as overall cardiology and heart surgery ranking, and the Centers for Medicare & Medicaid Services Hospital Compare was used to extract CABG volume and 30-day mortality. Spearman correlation coefficients were used to assess possible relationships. Expert opinion on risk adjustment and program evaluation was incorporated. RESULTS: Correlations between Society of Thoracic Surgeons star rating and U.S. News & World Report overall ranking in cardiology and heart surgery (r = 0.15) and Centers for Medicare & Medicaid Services 30-day mortality (r = -0.27) were poor. Society of Thoracic Surgeons star rating correlated weakly with U.S. News & World Report CABG ratings (r = 0.33) and with Centers for Medicare & Medicaid Services CABG volume (r = 0.32), whereas the latter 2 correlated moderately (r = 0.52) with each other. Of the 75 centers with accredited cardiac surgery training programs, 13 (17%) did not participate in Society of Thoracic Surgeons public reporting. Important gaps were identified in risk assessment, and potential solutions are proposed. CONCLUSIONS: Correlations between current CABG public reporting systems are weak. Further work is needed to refine and standardize CABG rating systems to more adequately capture the scope and complexity of an individual center's clinical practice and to better inform patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Medicare , Humanos , Idoso , Estados Unidos , Ponte de Artéria Coronária/efeitos adversos , Hospitais , Risco Ajustado
16.
Int J Cardiol ; 370: 112-121, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36370873

RESUMO

AIMS: To evaluate all-cause mortality in ViV-TAVI versus redo SAVR in patients with failed bioprostheses. METHODS: Study-level meta-analysis of reconstructed time-to-event data from Kaplan-Meier curves of non-randomized studies published by September 30, 2021. RESULTS: Ten studies met our eligibility criteria and included a total of 3345 patients (1676 patients underwent ViV-TAVI and 1669 patients underwent redo SAVR). Pooling all the studies, ViV-TAVI showed a lower risk of all-cause mortality in the first 44 days [hazard ratio (HR) 0.67, 95% confidence interval (CI) 0.49-0.93, P = 0.017], with an HR reversal after 197 days favoring redo SAVR (HR 1.53; 95% CI 1.22-1.93; P < 0.001). Pooling only the matched populations (1143 pairs), ViV-TAVI showed a lower risk of all-cause mortality in the first 55 days [hazard ratio (HR) 0.63, 95% confidence interval (CI) 0.45-0.89, P < 0.001], with a reversal HR after 212 days favoring redo SAVR (HR 1.57; 95% CI 1.22-2.03; P < 0.001). The Cox regression model showed a statistically significant association of prosthesis-patient mismatch (PPM) with all-cause mortality during follow-up for ViV-TAVI (HR 1.03 per percentage increase in the study- and treatment arm-level proportion of PPM, 95% 1.02-1.05, P < 0.001). CONCLUSION: ViV-TAVI is associated with a strong protective effect immediately after the procedure in comparison with redo SAVR, however, this initial advantage reverses over time and redo SAVR seems to be a protective factor for all-cause mortality after 6 months. Considering that these results are the fruit of pooling data from observational studies, they should be interpreted with caution and trials are warranted.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
17.
J Card Surg ; 37(12): 5599-5602, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378875

RESUMO

INTRODUCTION: Robotic-assisted coronary artery bypass grafting (CABG) outcomes in patients with a high society of thoracic surgery (STS) score in urgent settings remain hindered. PRESENTATION OF CASE: A high-risk female patient presented with dyspnea and low ejection fraction (EF = 15%) and was diagnosed with pulmonary edema post myocardial infarction. She was medically stabilized with intraaortic balloon pump and the heart-team decided to intervene with off-pump robotic hybrid coronary revascularization (HCR). The patient had the planned with left internal mammary artery (LITA) anastomosis to the left anterior descending artery (LAD) and the postoperative recovery was uneventful and patients discharged after few days at home. DISCUSSION: CABG has proven to be superior to percutaneous coronary intervention (PCI) even when guided by fractional flow rate and using the last generation stents according to fractional flow reserve versus angiography for multivessel evaluation 3 clinical trial. In moderate SYNTAX score patients that have been historically (SYNTAX trial) treated with multivessels PCI, robotic CABG has been shown to offer the advantage of LITA-LAD in combination with stent for non-LAD territory. CONCLUSION: High-risk, fragile patients, with low EF and high STS score that undergo urgent CABG can benefit from heart-team collaboration, and HCR is an important tool in the armamentarium.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico , Resultado do Tratamento
18.
J Card Surg ; 37(12): 5653-5662, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378946

RESUMO

Over the last decade, sutureless valves (Perceval, LivaNova PLC) were brought to the market as an alternative to stented valves for patients requiring surgical aortic valve replacement (SAVR). However, Perceval demands special steps for implantation, among which we can mention specific training for the surgical team members. Sternal-sparing cardiac procedures are conceived to limit surgical trauma, but the technical requirements and preoperative planning are more challenging than those for conventional sternotomy. SAVR is frequently carried out through an upper hemisternotomy, but the right anterior thoracotomy (RAT) represents an even less traumatic, technical advancement. In the context of SAVR with RAT, Perceval has been considered the "perfect marriage." In patients with bicuspid aortic valve (BAV), some surgeons initially avoided the Perceval valve but, with growing experience, the prosthesis has been used for a wide variety of indications. According to an international consensus statement recently published, there are 3 BAV types: the fused BAV, the 2-sinus BAV and the partial-fusion BAV, each with specific phenotypes. The 2-sinus BAV has 2 cusps, roughly equal in size and shape, each cusp occupying 180° of the annular circumference, with only 2 aortic sinuses, resulting in a 2-sinus/2-cusp valve without raphe and with 180° commissural angles. Since the elliptic aortic annulus in BAV patients poses a challenge for sutureless valves and the RAT approach has been increasingly adopted for minimally invasive SAVR, our description of the surgical technique focuses on the specific procedural details in the scenario of 2-sinus BAV laterolateral phenotype.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Doença da Válvula Aórtica Bicúspide/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
20.
J Card Surg ; 37(12): 4256-4266, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36086999

RESUMO

OBJECTIVES: To evaluate the long-term outcomes of a conservative approach (with proximal aortic replacement with or without hemiarch replacement) versus an aggressive approach (with total aortic arch replacement) in the treatment of acute type A aortic dissection (ATAAD). METHODS: We performed a pooled analysis of Kaplan-Meier-derived individual patient data from studies with follow-up comparing the aforementioned approaches to treat patients with ATAAD. RESULTS: Eighteen studies met our eligibility criteria, comprising 5243 patients with follow-up (Conservative: 3676 patients; Aggressive: 1567 patients). We observed a statistically significant difference in overall survival favoring the aggressive approach (hazard ratios [HR] 0.86, 95% confidence interval [CI] 0.76-0.98, p = .022), but no statistically significant difference in the risk of reoperation (HR 0.89, 95% CI 0.66-1.2, p = .439) in the overall follow-up. Landmark analyses revealed that, in the first 3 months after the procedure, mortality rates were comparable between conservative and aggressive approaches (HR 1.04, 95% CI 0.88-1.24, p = .627), but the results beyond 3 months showed improved survival in patients undergoing the aggressive surgical procedure (HR 0.71, 95% CI 0.59-0.85, p < .001). The landmark analyses also revealed that, in the first 7 years after the procedure, reoperation rates were comparable between the approaches (HR 1.03, 95% CI 0.76-1.40, p = .848), but the results beyond 7 years showed a lower risk of reoperation in patients undergoing the aggressive surgical procedure (HR 0.10, 95% CI 0.01-0.75, p = .025). CONCLUSION: The aggressive approach seems to confer better long-term survival and lower risk of the need for reoperation in the follow-up of patients treated for ATAAD.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Humanos , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Doença Aguda , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Reoperação , Aneurisma da Aorta Torácica/cirurgia , Fatores de Risco , Aorta Torácica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...